Welcome!
PTS Data Center Solutions designs, builds, and operates data centers that are great for companies and their people, but better for the planet. Visit us at www.ptsdcs.com.
Tags
Links
PTS Data Center Solutions, Inc.
PTS has both Facilities and IT experience, having integrated and tested many of the best-of-breed technologies the industry has to offer.PTS Design & Engineering
PTS specializes in all aspects of architectural as well as mechanical, electrical, and plumbing (MEP) and building services engineering for virtually every type of building or structure.PTS IT Services & Solutions
Managing IT so you can make better... smarter... faster... and more economical data-driven decisions
Wednesday, May 09, 2012
Monday, May 07, 2012
End-to-End Real-Time Power Management from your IT Devices to your Utility Feeds
Famed management consultant Peter Drucker once said, "If you can't measure it, you can't manage it." That statement holds true for data center power management where managers need to be able to effectively monitor and manage power consumption within the facility at both the IT device and utility level.
At the device level, PTS is bullish on the Rack Management Platform (RaMP) solution developed by No Limits Software. RaMP automates the build polls and trends power right from the IPMI chip and through service processors such as iLO & DRAC. It also makes recommendation to take specific action based upon analytics.
At the facility level, the PowerLogic Power & Energy Monitoring System from Square D monitors and measure every level of facility power infrastructure from the utility feed, to main distribution panels, to the transformers, PDU's and circuit breakers feeding data center IT equipment.
Other solutions such as Power Assure provide combined IT & Facilities power monitoring solutions. Also for consideration are other Power Monitoring solutions as well as integrated Data Center Infrastructure Management solutions from Raritan, Packet Power, nlyte Software, Emerson Network Power, RF Code, ServerTech, and Geist to name a few.
To learn more about PTS' Energy Management Services & Solutions, visit us here or contact us.
Monday, April 09, 2012
PTS Exhibiting at Con Edison Energy Efficiency Summit 2012
Join PTS Data Center Solutions at the Con Edison Energy Efficiency Summit on May 1st at the Hilton New York Hotel. The second annual event brings together building contractors, manufacturers, and consultants working to reduce business energy consumption. Many reports state greater than 50% of the power burden for businesses resides in the data center and its IT and facility support infrastructure. Leveraging our proprietary data center & energy usage assessment approach, PTS provides actionable recommendations to reduce energy consumption and green the data center.
Register and get the event details here or learn more about PTS' role as a Market Partner to ConEd focused on assessing and improving energy efficiency within data centers and computer rooms.
Wednesday, April 04, 2012
Data Center Management Gotchas
According to a Ponemon Institute study, an outage can cost an organization an average of about $5,000 per minute. That’s $300,000 in just an hour. |
- Those high-density predictions finally are coming true
- Data center managers will replace servers three times before they replace UPS or cooling systems
- Downtime is expensive
- Water and the data center do not mix – but we keep trying
- New servers use more power than old servers
- Monitoring is a mess
- The IT guy is in charge of the building’s HVAC system
- That patchwork data center needs to be a quilt
- Data center on demand is a reality
- IT loads vary – a lot
As a Diamond Solutions Partner for Emerson, PTS Data Center Solutions leverages our engineering and architectural experience in designing and building data centers with our IT network, storage, virtualization expertise to avoid the surprises mentioned in the article before they result in significant downtime. To learn more contact PTS today.
Monday, February 27, 2012
An Industry Look at Locking IEC Power Connections
1) IEC Lock. This solution is universal on the equipment side and addresses the problem by having a button that slides to engage a pin that drops down on the ground plug. This is now UL approved.
2) IEC C14 Grip Secure Insert. This solution is not UL approved, and only addresses the PDU side, but it is very inexpensive.
3) APC / V-Lock by Schurter. The solution works well, but the APC PDU must be 8000 series and the equipment outlets must be changed out to also secure the IEC receptacle on the equipment side.
4) Raritan ETO Outlets. Some Raritan PDU’s are available with this option, designated by an –E2 on their parts list. It appears to work the same as IEC Lock, but they do not address the equipment side only the PDU side.
5) Server Technology Retention Clips. Server Technology provides retention clips that clip into their power strips only and clip around the head of the IEC power cord. This solution only addresses the PDU connection and works well with ServerTech power cords. It does not work with all IEC power cords as there are variances in the size of the IEC C14 heads and input cords.
6) HP PDU Notches and Bands. HP now has notches on their PDU's and they provide bands to secure the IEC power cords to the PDU. This only addresses the PDU side of the problem.
Would like to hear about your experiences and what your organization is doing to address this issue. See this link for more information on the solutions we have found.
Guaranteeing IEC Secure Power Connections
Have you been experiencing this issue due to appliance vibration or accidental disconnects when maintenance and cabling work is performed in your racks?
If so, PTS recommends and distributes five different IEC Secure Power Connections to meet the needs of data center operators. To learn more click here.
Wednesday, February 15, 2012
Retail Industry PCI Compliance Support
To support this requirement, PTS Data Center Solutions has teamed up with Fortinet as its 'go to' supplier in helping our retail clients reign in these costs and ease management of PCI compliance. And, not just we recognize that, check out the IDC, Gartner, and Frost Market Summary Report.
To learn more, read our recent IT Solutions Bulletin - Fortinet for Retail Industry PCI Compliance.
Monday, January 16, 2012
Data Center Maintenance Management Solution Version 2.0 Available Today
The software works with any of the Data Center Infrastructure Management (DCIM) products available today which include discovery tools, real-time monitoring tools, BMS solutions, and IT monitoring and management solutions. DCMMS is used to maintain facility support infrastructure products in many data centers and from many manufacturers.
PTS uses DCMMS as a key component of its Data Center Managed Maintenance Service offering. The service provides various support levels from software only to software and asset maintenance tracking to full 7x24 outsourcing of asset maintenance management.
To learn more Click Here or Contact PTS.
Thursday, December 29, 2011
UPS Configuration Availability Rankings
Peter Sacco, President & Founder, PTS Data Center Solutions, recently wrote a new white paper on UPS Configuration Availability Rankings.
Reliance on technology has elevated data center availability from a lofty goal to an absolute necessity. As such, the configuration of the UPS system is vitally important in achieving high-availability with respect to the power side of the universe. This paper explores a number of different UPS configurations, how they contribute to availability, and who manufactures them.
Pete's conclusion is that UPS configurations depend upon a number of factors including: level of availability required/desired (i.e. Tier class), IT load requirements, power input, and budget. Understanding these factors and their impact on UPS configuration and design will result in a suitable UPS purchase to meet user and IT load requirements.
For the complete white paper, please visit the PTS Media Library (log-in required) or contact us to receive a complimentary PDF.
Friday, December 16, 2011
Which is higher availability 2N or N+2?
Most understand that modular solutions improve efficiency, but many believe that a 2N design is higher availability than a N+2 design. Not so fast, 2N is 2 component failures away from an outage where N+2 in a modular design is typically 3 components away from having reduced capacity. So why doesn't Uptime consider N+x designs for any of the critical components in it's tiering ratings? For that matter why isn't there a data center rating system that considers the improved availability of N+x designs?
Search all PTS Sites
Recent Posts
Hyperconvergence eBook
PTS Open Lease
Popular Posts
-
A number of clients have asked us about the viability of replacing their ‘wet’ sprinkler systems with a dry-type fire suppression system, s...
-
Data centers are facing unprecedented challenges and opportunities as they cope with the growing demand for generative AI and other cutting...
-
Reopen with Confidence As the world enters the next phase of the pandemic, businesses are forced to make changes to accommodate not only a ...
-
Last week I posted the following discussion question in our Computer Room Design networking group at LinkedIn.com. I’m really impressed wit...
-
How Edge Data Center Solutions are Evolving for New End User Needs What You’ll Learn: Why do edge facilities require more customization? ...
-
As anticipation builds around Nvidia’s forthcoming announcements, a critical issue has resurfaced within the data center domain: the sign...
-
PTS Data Center Solutions Consultants are finding most data center facilities operators don’t want to burden or use their expensive network...
-
Why Make Data-Driven Decisions? For businesses, the importance of data analytics and business intelligence cannot be overstated. Small busin...
-
I’m excited to announce that PTS has launched a strategic distribution relationship with Dell Corporation which includes the full breadth of...
-
Thank you to everyone who joined PTS Data Center Solutions and the New York Jets last night at Power Camp 2009, hosted at the new Jets Tra...